HUAYI generator AC withstand
voltage resonance tester system is composed of generator AC withstand voltage
test, generator withstand voltage tester, frequency AC withstand voltage test,
generator withstand voltage tester equipment and generator serious resonance equipment.
Generator AC withstand voltage tester is aimed to the frequency AC withstand voltage
test of hydroelectric generator with 250MW capacity of single machine and below.
As the development of the electric system, the capacity of the equipment more and more larger, for example, the capacity of single machine of the thermoelectric generator group is more than 1000MW, the capacity of single machine of the hydroelectric generator group is more than 800MW, if use traditional equipment (frequency test transformer) , need large capacity, test transformer, voltage regulator are very heavy, it is not convenient for field test. Serial resonant system is better than traditional equipment in power capacity, device weight, measured waveform and cost. It is special designed for the AC voltage withstand test for hydroelectric generator which its single machine capacity ≤250MW.
1. Need smaller power capacity. The power of the serial resonant system generate high voltage and high current by resonant reactor and measured capacitance, in the whole system, power source only provides the power consumption part of the system, so the required power is only 1/Q of the measured capacity.
2. Lighter and smaller volume. Without the heavy power voltage regulating device and test transformer, and excited power is only 1/Q of the measured capacity. The weight and volume are only 1/10-1/30 of the common devices.
3. Improve the output voltage waveform. Resonant power source is resonant filter circuit, which can improve the output voltage waveform distortion, get better sin wave, and effectively prevent the harmonic peak value breakdown the measured equipment.
4. Prevent the high current to burn out the fault point, for the serial resonant; the circuit will be dissonant as soon as the insulation weakness of the measured device was broken down, the loop current fast decrease to the 1/Q of the normal measured current. But for the parallel resonant or test transformer to do voltage withstand test, the breakdown current , these two compare, short circuit current and breakdown current different in hundreds times. So the serial resonant system can easily find out the insulation weakness, and do not worry about the heavy short circuit current burn out the fault point.
5. Without any recovery over-voltage. When the measured equipment was broken down, it lost the resonant conditions, high voltage immediately disappear, electric arc immediately burn out, and it is a long process to recover the voltage, easily to power off before it get to the flashover voltage another time, it is a long process, without any recovery over-voltage.
1.
The device with over-voltage, over-current, and system
dissonant (flashover) protection functions.
2.
Single machine light in weight, less than 40kg, convenient
for field test.
3.
With four working modes, convenient for customers to select,
improve the measurement speed working mode: full automatically, manual control,
auto tuning manual voltage boosting.
4.
Can store and print the test results, convenient for
customers to identify and review.
5.
The scanning starting point can be set up randomly at rated
range when the device auto scanning, the direction can be up or down, the LCD
will show the scanning curve, convenient for customers to check if found the
resonant point.
6.
Adopts DSP platform technology, convenient to add or reduce
the functions and upgrade according customers’ requirements, make the
man-machine interface be more humanization.
Rated
voltage
40kV---meet
10kV generator AC withstand voltage test
Output voltage
waveform distortion rate
<1.0%
Continuous
working time
5 min one time under
rated condition
Quality Factor
Q>50
Quality factor
at full load in generator test
Q>15(load related)
Input power
Single phase 380V
Frequency
Range
20Hz~300Hz
Measurement
accuracy
1.50%
The device with
over-voltage, over-current, and system dissonant (flashover) protection
functions
Serial Number |
Name | Amount |
1 |
Adjustable reactor |
one |
2 |
Compensation capacitor |
one |
3 | Motivator | one |
4 |
Voltage divider |
one |
5 |
Variable
frequency source |
one |
6 | Reactor | two |
7 |
Specification |
one |
8 |
Inspection
Report |
one |
9 |
Certification |
one |
Your Name: | |
E-mail: | |
Phone: | |
Title: | |