XZB series consists of frequency conversion power supply, excitation transformer, reactor and capacitance divider. The capacitor and reactor of the tested equipment form the connection way of series resonance. The voltage divider is connected in parallel to the tested equipment to measure the resonant voltage as overvoltage protection signal as well. The frequency modulation power output is coupled to the series resonance circuit by the excitation transformer, providing the excitation power of series resonance. It exerts series resonance principle, uses excitation transformer to motivate series resonant loop, and adjust the output frequency of the director to make the loop inductance L and measured equipment C in series resonant, and the resonant voltage is the voltage added to the tested equipment.XZB series is widely used in electric power, metallurgy, petroleum, chemical industry and other industries, apply to large capacity, high voltage capacitance test and preventive test.
1. This withstand
voltage equipment has small volume, light weight and portable test system.
2. This system requires that the weight can be moved on site by a single person should not exceed 30kg, and it can be moved by two people should not exceed 60kg, therefore it is suitable for on-site working.
3. The power
supply adopts 220V single-phase power supply or 380V single power supply, which
is convenient for on-site power collection.
4. The reactor adopts dry epoxy
pouring, which is beautiful and reliable, suitable for all kinds of cables.
6. Equip with the function of monitoring peak value according to international standard, which can monitor high voltage test waveform in real time.
7. Easy to operation, big LED screen.
8. With its own micro printer, print and save test data at any time.
Temperature
-10℃~40℃
Relative
humidity
≤95%, no condensation
Altitude
≤3000 meter
Rated Capacity
1040kVA
Input Power
Three phase 380V,
Frequency 50Hz
Rated voltage
130kV
Rated Current
8A
Output
frequency
30-300Hz
Voltage
waveform
Sine Wave, waveform
distortion rate<1.0%
Working time
Continuous
working time 60min under rated load, overvoltage 1.1 times, 1minute
Temperature
Rise
Continuous working
time 60min under rated load, temperature rise≤65K
Quality Factor
Q≥30(f=45Hz)
Measurement
Accuracy
System Effective
value 1.5